Slide title: Example (Benchmark Structure)
Slide image: NEESWOOD logo at top right.
Graph 1: Phase 5 Test Level 4 (DE)
Test Measurement
East-West
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(5.19 mm, 136 kN)
(-5.17 mm, -118 kN)
Graph 2: Phase 5 Test Level 4 (DE)
Test Measurement
North-South
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(35.6 mm, 273 kN)
(-40.9 mm, -269 kN)
Graph 3: Phase 5 Test Level 4 (DE)
Numerical Result
East-West
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(5.21 mm, 167 kN)
(-7.10 mm, -184 kN)
Graph 4: Phase 5 Test Level 4 (DE)
Numerical Result
North-South
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(32.5 mm, 268 kN)
(-36.3 mm, -255 kN)
Graph 5: Phase 5 Test Level 5 (MCE)
Test Measurement
East-West
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(12.0 mm, 127 kN)
(-9.12 mm, -146 kN)
Graph 6: Phase 5 Test Level 5 (MCE)
Test Measurement
North-South
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(78.1 mm, 313 kN)
(-101 mm, -351 kN)
Graph 7: Phase 5 Test Level 5 (MCE)
Numerical Result
East-West
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(10.4 mm, 248 kN)
(-8.11 mm, -179 kN)
Graph 8: Phase 5 Test Level 5 (MCE)
Numerical Result
North-South
Y-axis: Base Sheer Force (kN)
X-axis: Central Roof Displacement (mm)
(92.3 mm, 252 kN)
(-86.0 mm, -249 kN)
Slide words:
- Comparison of global story hysteresis showed good
agreement with base shear prediction
|